Several important precautions when actually using the rolling box pilling and pilling tester

Author:QINSUN Released in:2023-10 Click:114

The Rolling Box Pilling Tester is used for pilling or snagging caused by normal wear and tear. It is equipped with a special controller and standard and other optional test speeds for testing. It is also equipped with an optional reverse system programmed at 30 rpm. It can be equipped with multiple pill boxes; it has forward and reverse functions; LCD screen displays all test parameters; it alarms when the experiment is completed and has good waterproof performance.

The pilling performance of textiles is a very complex indicator because it is affected by many factors, including fiber type and its blended products, fiber size, yarn and fabric structure, and processing. finishing of the fabric. . The anti-pilling properties of fabrics are more complicated when actually worn than under ordinary conditions, and actual wearing par consumers is more complicated than in laboratory conditions.

Several important precautions for using the Roller Box Pilling Tester:

1. Clean the testing room before the test starts and after the test is finished. You can use a vacuum dust remover to remove test residue. Clean objects to avoid residual substances.

2. Check the laboratory for leaks at least once a week.

3. Clean the cork covering regularly with a suitable cleaning solvent.

4. Check regularly whether the control panel keys and screws of various parts are loose.

5. Samples of the same sample should be tested in different test chambers to avoid affecting the test accuracy.

6. When the sample is stuck by the impeller, stop the test, remove the sample and clean the impeller with cleaning fluidyage or water. Once dry, continue testing.

7. During operation, the test chamber should be checked frequently. If the test is wrapped around the impeller and does not turn over, or is stuck at the bottom or side of the silo, it will remain stationary. Close the air valve, turn off the air flow, stop the test and remove the sample. Record unexpected terminations or other abnormal test conditions.